Series WV-DV™

Products » Residential Boilers » Series WV-DV™

The Series WV-DV™ boiler is a direct vent, cast iron, oil-fired boiler for residential, hot water systems. This fully packaged, ready-to-install boiler is ideal for simple installations where a chimney is not available or where the existing chimney is no longer safe to use. The Series WV-DV™ boiler is also ideal for converting heating systems in houses with electric baseboard or a heat pump. This sealed combustion boiler is also suitable for new homes with tight construction. The large water content and wet-base section design of the Series WV-DV™ boiler reduce on/off cycling.

An ASME safety relief valve, pre- and post-purge burner controls and ETL design certification make the Series WV-DV™ boiler a safe and dependable choice.

Type: Residential
Construction: Cast Iron
Fuel: Oil-Fired
Input: 105 to 182 MBH
Output: 92 to 158 MBH
Venting: Direct Vent
Trim: Water
Combustion: Flame Retention Burner,
Sealed Combustion Burner

 

  • Direct Vent
  • Fully Packaged, Cast Iron, Oil Boiler
  • Hot Water Boiler
  • Large Water Content, Wet-Base Section Design
  • High Efficiency, Sealed Combustion, Flame Retention Burners
  • Solid State Burner Control with Pre- and Post-Purge
  • ETL Design Certified

Don't see the information you need? See the "Related Documents" tab for product resource downloads.

  •  
Series WV-DV™ Water Content, Gallons
Model Number1 Input2 Heating Capacity3, MBH Net Ratings Water4, MBH AFUE5, %
GPH MBH
WV-DV-03* 0.75 105 92 80 86.7* 11.75
WV-DV-03* 0.85 119 103 90 85.9* 11.75
WV-DV-03 1.10 154 131 114 84.1 11.75
WV-DV-04* 1.15 161 141 122 86.7* 14.75
WV-DV-04* 1.30 182 158 137 86.0* 14.75

* As an ENERGY STAR® Partner, PB Heat has determined that these firing rates meet the ENERGY STAR guidelines for energy efficiency.

1 Boiler Model No. may have the following suffix letters: WPC = Water Package w/Burner & Circulator; WPCT = Water Package w/Burner, Circulator & Tankless Coil.

2 Firing rate is based on a fuel oil with a heating value of 140,000 BTU per gallon. Burner input based on maximum altitude of 2,000 ft. – for other altitudes consult factory.

3 Heating capacity based on D.O.E. Testing procedure with 13.0% CO2 and –0.02 in. water column draft in firebox.

4 The Net Ratings shown include allowance for normal piping pick-up load.

5 Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) ratings are based on U.S. Government test. Before purchasing this appliance, read important information about its estimated annual energy consumption or energy efficiency rating that is available from your retailer.

Don't see the information you need? See the "Related Documents" tab for product resource downloads.

Series WV-DV™ Boiler Dimensions

Boiler Model Number Jacket Rear of Jacket to c/l of Vent "B" Right of Jacket to c/l of Flue Vent Diam.
Width Depth "A" Top to Floor
WV-DV-03 22 1/8" 14 1/8" 35" 7 1/16" 8 5/16" 4"
WV-DV-04 22 1/8" 18 1/8" 35" 9 1/16" 8 5/16" 4"